• 200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC
  • 200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC
  • 200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC
  • 200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC
  • 200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC
  • 200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC

200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC

Task: Program
Function: Automatic Control
Certification: ISO: 9001, CE
Condition: New
Customized: Customized
Delivery Time: 1-2 Business Day After Payment Confirmed
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
UN 214-1BD23-0XB8
Transportation
TNT, DHL, FedEx, Aramex, UPS, etc.
Net Weight
0.5kg
Trade Term
FOB Shenzhen
Compatibility
Siemens
Transport Package
CTN
Specification
CE, SGS, TUV ISO9001
Trademark
UniMAT
Origin
China
HS Code
853710119
Production Capacity
50, 000/Year

Product Description

UniMAT CPU 14DI / 10DO Programming Logic Controller Compatible with Siemens PLC
 

1) 14DI/10 DO with relay

2) Communication Ports: 2RS - 485, both support PPI protocol 

3) Supports expansion modules : 7 modules 

4) Compatible with Siemens 224 CPU 

5) 3-year warranty   

6) Siemens software is ok.


200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC
200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC 200 PLC with 214 AC / DC / Relay Equivalent S7 214/216 PLC
Technical specifications  
Model CPU224 AC/DC/Relay
Physical characteristic  
Dimensions(W x H x D)(mm) 120.5× 80× 62
Power consume 10W
Memory   
Program memory size  
With run mode edit 25K bytes
Without run mode edit 50K bytes
Data memory 20408bytes
I/O  
Local digital inputs 14 inputs
Local digital outputs 10 outputs
Digital I/O image size 256(128 inputs/128 outputs)
Analog I/O image size 64(32 inputs/32 outputs)
expansion modules allowed (Max) 7 modules
intelligent modules allowed (Max) 7 modules
Pulse catch inputs 14
High-speed counters 6 counters total
Single phase 6 at 30KHz
Two phase 4 at 20KHz
Pulse outputs -
General  
Timer Total number: 256(1ms: 4; 10ms: 16; 100ms: 236)
Counters  256
Internal memory bits stored on power down 256
Time interrupts 2 with1ms resolution
Edge interrupts 4 up and/or 4 down
Analog adjustment 2 with 8 bit resolution
Boolean execution speed 0.08µ s per instruction
Real Time Clock Built-in
Communications Built-in  
Ports 2 RS-485 ports, within1standard PPI port
PPI Baud Rates 9.6, 19.2 and 187.5 kbaud
Freeport Baud Rates 1.2kbaud to 115.2kbaud
Max. cable length per segment With isolated repeater: 1000 m up to 187.5kbaud, 1200 m up to 38.4kbaud
Without isolated repeater: 50 m
Max. number of stations 32 per segment, 126 per network
Max. number of masters 32
Peer to peer(PPI Master Mode) Yes
Power  
Input voltage 85  to 264 V AC(47 to 63Hz)
Input current 60/30mA while CPU only at  120/240 V DC
200/100mA while Max. load at  120/240 V DC
Inrush current 20A at 264 V AC
Isolation(field to logic) 1500V AC
Hold up time(loss of power) 1s at  120/240 V DC
Sensor voltage 20.4  to 28.8 V AC
Current limit 1.5A peak, thermal limit non-destructive
Ripple noise (sensor to logic) Less than 1V peak-to-peak
Isolation (sensor to logic) Not isolated
CPU Digital Input
Specifications
 
Built-in digital input 14 inputs
Input type PNP/NPN
Rated voltage 24 V DC at 4mA
Max. continuous  permissible voltage 30 V DC
Surge voltage 35 V DC for 0.5s
Logic " 1"   voltage range 15 to 30 V DC
Logic " 0"   voltage range 0 to 5 V DC
Input delay Selectable (0.2 to12.8ms)
Connection of 2-wire proximity sensor (Bero) 1mA
Premissible leakage current (Max. )
Isolation (field to logic) Yes
Optical galvanic 500 V AC for 1minute
Isolation groups Refer to Wiring diagram
High Speed Counter (HSC) input rate  
HSC logic level 1(15 TO 30 VDC) 20K Hz (Single phase), 10K Hz (Tow phase)
HSC logic level 1(15 TO 26 VDC) 30K Hz (Single phase), 20K Hz (Tow phase),
Inputs on simultaneously all
Cable length Max.  
Shielded 500m normal inputs, 50m HSC inputs
unshielded 300m normal inputs
CPU Digital
Output Specifications
 
Built-in outputs 10 outputs
Output type Dry contact
Rated voltage 24 V DC or 250 V AC
Voltage range 5  to  30 V DC or 5 to 250 V AC
Surge current (Max. ) 5A for 4s at 10% duty cycle
Logic " 1"   (Min) -
Logic " 0"   (Max) -
Rated current per point(Max. ) 2.0A
Rated current per common(Max) 10A
Leakage current (Max) -
Lamp load (Max) 30W DC; 200W AC
Inductive clamp voltage -
On State resistance (contact) 0.2Ω (max. when new)
Isolation  
Optical (galvanic, field to logic) -
logic to contact 1500V AC, 1 minute
Resistance (logic to contact) 100MΩ
Isolation groups Refer to wiring diagram
Delay(Max)  
Off to on -
On to off -
Switching 10ms
Pulse frequency (Max. ) 1Hz
Lifetime mechanical cycles 10, 000, 000(no load)
Lifetime contacts 100, 000(rated load)
Outputs on simultaneously All at 60C(horizontal)
All at 50C(Vertical)
Connecting two outputs in parallel No
Cable Length (Shielded) 500m
Cable Length (unshielded) 150m
Order number UN 214-1BD23-0XB0

 

Send your message to this supplier

*From:
*To:
avatar Ms. Sandy Shi
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now