Customization: | Available |
---|---|
Weight: | 230g |
Power Consumption: | 5.5W |
Still deciding? Get samples of US$ 150/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
odel | SM 1223 DI 8x24 V DC DQ 8×RLY |
SM 1223 DI 16×24 V DC DQ 16×RLY |
SM 1223 DI 8×24 V DC DQ 8×24V DC |
SM 1223 DL16x24 V DC DQ 16×24V DC |
Order number | UN 223-1PH32-0XB0 | UN 223-1PL32-0XB0 | UN 223-1BH32-0XB0 | UN 223-1BL32-0XB0 |
dimensionWxHxD(mm) | 45x100x75 | 70x100x75 | 45x100×75 | 70x100x75 |
weight | 230 g | 350g | 210g | 310 g |
Power consumption | 5.5 W | 10 W | 2.5 W | 4.5 W |
Current consumption (SM bus) | 145 mA | 180 mA | 145 mA | 185 mA |
Current consumption (24VDC) | Each point input used is 4mA 7mA per relay coil used |
Each point input used is 4mA 7mA per relay coil used |
150 mA | 200 mA |
Digital input | ||||
Enter points | 8 | 16 | 8 | 16 |
Type | Sink/Source type (IEC Class 1 sink type) | |||
Rated voltage | 24V DC at 4 mA, nominal | |||
Allowed continuous voltage | Max 30V DC | |||
Surge voltage | 35VDC, lasting 0.5s | |||
Logic 1 signal (minimum) | 2. 15V DC at 5mA | |||
Logic 0 signal (maximum) | 5 V DC at 1 mA | |||
Isolation (field side and logic side) | 707VDC (type test) | |||
Isolation group | 2 | 2 | 2 | 2 |
Filter time | 0.2, 0.4, 0.8, 1.6, 3.2, 6.4 and 12.8ms (selectable, 4 in a group) | |||
Number of inputs connected simultaneously | 8 | ·8 (no adjacent points), at 60ºC (horizontal) or 50ºC (vertical) ·16, at 55ºC (horizontal) or 45ºC (vertical) |
8 | 16 |
Cable length (meter) | 500 (shielded); 300 (unshielded) | |||
Digital output | ||||
Output points | 8 | 16 | 8 | 16 |
Type | Relay, dry contact | Solid state -MOSFET (source type) | ||
Voltage range | 5-30VDC or 5-250VAC | 20.4 -28.8V DC | ||
Logic 1 signal at maximum current | - | Min20 V DC | ||
Logic 0 signal with 10 KQ load | - | Max0.1V DC | ||
Current (maximum) | 2.0A | 0.5 A | ||
Lamp load | 30 W DC/200 WAC | 5 W | ||
On-state contact resistance | 0.2 Ω maximum for new equipment | Max0.6 Q | ||
Leakage current per point | - | Max 10μA | ||
Inrush current | 7A with contacts closed | 8A maximum duration 100 ms | ||
Overload protection | None | |||
Isolation (field side and logic side) | 1500VAC (coil and contacts) None (coil and logic side) |
707V DC (type test) | ||
Isolation group | 2 | 4 | 1 | 1 |
Current at each common terminal | 10 A | 8A | 4 A | 8 A |
Inductor clamping voltage | -- | L+-48 V,1W loss | ||
Switching delay | Maximum 10 ms | The longest time from disconnection to connection is 50μs The longest time from connecting to disconnecting is 200μs |
||
Mechanical life (no load) | 10,000,000 open/close cycles | |||
Contact life under rated load | 100,000 open/close cycles | |||
Behavior during RUN-STOP | Previous value or replacement value (default value is 0) | |||
Number of outputs switched on simultaneously | 8 | ·8 (no adjacent points), 60°C (horizontal) or 50°C (vertical) ·At 16,55ºC(horizontal) or 45ºC(vertical) |
8 | 16 |
Cable length (meter) | 500(shielded);150(unshielded) |