Customization: | Available |
---|---|
Task: | Adjust |
Structure: | Open-Loop |
Still deciding? Get samples of US$ 1750/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Basic application functions | |
Torque raise at low frequency |
To improve low frequency torque about 0.1%-30% under V/f control and sensorless speed vector control through raising voltage and torque. |
V/F Curve | Linear type, multi-point type |
Acceleration and deceleration curve |
Linear type or Model S acceleration and deceleration: Three groups acceleration and deceleration time; Acceleration and deceleration time range: 0-3200s. |
Automatic Voltage Regulation (AVR) | When network voltage changes, it could keep constant output voltage. |
Built-in PID | Convenient to realize process control under close-loop control system. |
DC braking | DC brake range: 0- maximum frequency; brake time: 0-20.0s; brake action current value: 0-100%. |
Jog control | To realize instant start and instant stop: jog frequency setting range: 0-20Hz: jog stop type: freedom/DC brake |
Jump frequency | Available to set three jump frequency points and related jump frequency ranges |
Multi-speed | Available to set 15 running frequencies through logic input terminals |
Input Sum | The algebraic operation of 2-way analog input is used as frequency setting to make frequency setting more intelligent |
2 sets of motor parameter switching | Available to set two sets of motor parameter and could freely switch each other in order to match currently droved motor. |
Electrical characteristics | |
Input voltage | AC3PH.380-480V.50/60Hz |
Output voltage | 0-480V. 0.5Hz-400Hz |
Control Mode | V/F control for constant torque. V/F control for quadratic load. vector control without PG, Energy-saving mode |
Switching frequency | 1.5kHz-12kHz, according to junction temperature automatically reduce the switching frequency |
Overload capacity | 150% of rated out current for 60s. 200% of rated output Current for 2s |
Control signal | ||
Frequency setting signal | Integrated operation keypad | Film switch(Press button), speed control knob (potentiometer) |
Outside signal |
Given UP/DOWN. analogue input. multi-speed. remote keypad and series communication |
|
Start-stop control signal |
Integrated operation keypad | Press button of 'RUN' and 'STOP' |
Outside signal | Logic input terminal. remote keypad and series communication |
Protective function | |
Protection for VFD | Input phase failure. output phase failure. under load monitor, over torque. under voltage. over current, over heat. short circuit among three phases |
Protection for Motor | Motor overheat, motor current limiting amplitude. motor over load. motor short circuit |
Control circuit characteristics | ||
Available inside power supply | 5V 24V |
5V DC 5%, maximun current 10mA, it is used for benchmark potentiometer 24V DC 5%, maximum current 100mA, it is used for logic input entrance |
Analog Input | AI1 | Voltage analog input: 0-5VDC, or 0-10VDC, impedance 30k Current analog input: 0.4-20mADC, impedance 250Ω Resolution: 10 digital A/D switch Factory default setting: 0-5VDC voltage input |
AI2 | Voltage analog input: 0-10VDC, or PTC probe input Resolution: 10 digital A/D switch |
|
Logic Input | LI1-LI8 |
0-24V DC power supply Positive logic (source), negative logic (sink) are optional, the factory default is negative logic There are 69 functions available such as forward. reverse. run. fault reset, and multi-speed and so on. Only 6 ways below 11KW (including): LI1-L16 |
Al1.Al2 | Al1 and Al2 could be set to logic input for RV32 frequency inverter with power below (including)11 kW. | |
Mandatory effective input | F309 and F310 are mandatory effective input. It will guarantee the set function effective during powering on. |
|
Analog Output | AO1,AO2 | Voltage analog output: 0-10VDC, minimum load impedance is 470Ω Current analog output: 0/4-20mA, maximum load impedance is 700Ω Resolution: 8 digital |
Logic Output | LO,CLO | Open collector. maximum current 100mA. maximum voltage 30VDC Optional for logic output or pulse output. factory default is logic output Output frequency. output current and given speed are optional |
Relay output | T1A,T1B,T1C T2A,T2B,T2C |
T1A constant open. T1B constant close. T1C public Point Relay output
T2A constant open, T2 B constant close, T 2C public point T2A. T2B. T2C Touch point capacity: 5A@250VAC. 5A@30VDC Many functions optional such as fault, alarm and set frequency reach |
Serial Communication | 2-way RS-485. MODBUS-RTU, RJ45 connection port |
Environmental characteristics | |||
Ingress protection IP20 |
IP20 | humidity | No condensed water or drip at 5-95% In accordance with IEC60068-2-3 Installation place Altitude |
Working temperature/storage temperature | -10-50ºC/-20-60ºC |
Installation place |
Room |
cooling method | Forced Air cooling | Altitude | 1000m or below (Derating is necessary when the altitude is higher than 1000m) |
Model (380V) | G Type (Heavy Load) |
P Type (Light Load) | Installation Dimensions(mm) | ||||
Rated input current (A) |
Rated output current (A) |
Motor Power (KW) | Rated input current (A) |
Rated output current (A) |
Motor Power (KW) | ||
(H1*W1 mm) | |||||||
RV32-T3-0R7G/1R5P | 3.6 | 2.6 | 0.75 | 6.4 | 4.1 | 1.5 | 195*66.5 |
RV32-T3-1R5G/2R2P | 6.4 | 4.1 | 1.5 | 8.7 | 5.5 | 2.2 | 195*66.5 |
RV32-T3-2R2G/3P | 8.7 | 5.5 | 2.2 | 10.9 | 6.9 | 3 | 195*66.5 |
RV32-T3-3G/4P | 10.9 | 6.9 | 3 | 14 | 9.5 | 4 | 195*66.5 |
RV32-T3-4G/5R5P | 14 | 9.5 | 4 | 20.7 | 12.6 | 5.5 | 253*90 |
RV32-T3-5R5G/7R5P. | 20.7 | 12.6 | 5.5 | 26.5 | 18.5 | 7.5 | 253*90 |
RV32-T3-7R5G/11P | 26.5 | 18.5 | 7.5 | 36.6 | 25 | 11 | 253*90 |
RV32-T3-11G/15P | 36.6 | 25 | 11 | 40 | 32 | 15 | 341*106 |
RV32-T3-15G/18P | 40 | 32 | 15 | 47 | 38 | 18.5 | 341*106 |
RV32-T3-18G/22P | 47 | 38 | 18.5 | 56 | 45 | 22 | 321*140 |
RV32-T3-22G/30P |
56 | 45 | 22 | 70 | 60 | 30 | 321*140 |
RV32-T3-30G/37P | 70 | 60 | 30 | 80 | 75 | 37 | 396*180 |
RV32-T3-37G/45P | 80 | 75 | 37 | 94 | 92 | 45 | 396*180 |
RV32-T3-45G/55P | 94 | 92 | 45 | 128 | 115 | 55 | 500*200 |
RV32-T3-55G/75P | 128 | 115 | 55 | 160 | 150 | 75 | 543*200 |
RV32-T3-75G/90P | 160 | 150 | 75 | 190 | 180 | 90 | 583*240 |
RV32-T3-90G/110P | 190 | 180 | 90 | 225 | 215 | 110 | 583*240 |
RV32-T3-110G/132P | 225 | 215 | 110 | 265 | 260 | 132 | 583*240 |
RV32-T3-132G/160P | 265 | 260 | 132 | 310 | 305 | 160 | 698*240 |
RV32-T3-160G/185P | 310 | 305 | 160 | 355 | 350 | 185 | 698*240 |
RV32-T3-185G/200P | 355 | 350 | 185 | 385 | 380 | 200 | 698*240 |
RV32-T3-200G/220P | 385 | 380 | 200 | 430 | 425 | 220 | 898*320 |
RV32-T3-220G/250P | 430 | 425 | 220 | 485 | 480 | 250 | 898*320 |
RV32-T3-250G/280P | 485 | 480 | 250 | 545 | 530 | 280 | 1078*320 |
RV32-T3-280G/315P | 545 | 530 | 280 | 610 | 600 | 315 | 1078*320 |
RV32-T3-315G/355P | 610 | 600 | 315 | 665 | 650 | 355 | 1078*320 |
RV32-T3-355G | 665 | 650 | 355 | 1060*350 | |||
RV32-T3-400G | 785 | 725 | 400 | 1060*350 | |||
RV32-T3-500G | 890 | 860 | 500 | 1060*350 | |||
RV32-T3-560G | 950 | 950 | 560 | 943*665 | |||
RV32-T3-630G | 1100 | 1100 | 630 | 943*665 | |||
RV32-T3-710G | 1280 | 1280 | 710 | 1100*665 | |||
RV32-T3-800G | 1380 | 1380 | 800 | 1100*665 | |||
Note:If the product is used for permanent magnet synchronous motor,pleaseadd code "E"to the order model. |
Q: Are you a trading company or manufacturer?
A: We are a manufacturer of PLC, HMI, and Ubox
Shenzhen headquarters, Wuhan Raynen R&D center, Dongguan production factory
Q: Is customized supported?
A: The PLC supports customized and accepts OEM and the delivery time is about 20 days
Q: Which kinds of the series PLC can be compatible with Siemens
A: Our UN200 /300 /1200 PLC and smart series can compatibility S7-200/ S7-300 / S7-1200 with high quality and nice price
Q: How about the warranty?
A: Unimat provides 36 month's warranty for all the goods, and product lifetime technical support
Q: Do you have any engineers for technical support when buying?
A: Of course. Our support team will help you select products, customize automation solutions, and provide equipment using training and other support you need.
Q: We have not cooperated before, how can we believe you?
A: We sincerely invite you or your domestic agent to visit our company and factory. We have been trustworthy for 20 years.
Q: How about the terms of payment?
A: Generally through T/T, Paypal and Western Union also accept.
Q: What about the shipment?
A: We can arrange shipment by DHL, FedEx, UPS, TNT, and EMS with competitive prices and good service, of course, you can also use your freight forwarders.
Q: What about the delivery time?
A: Normally in 1 Week.