Unimat VFD 3kw Three Phase Variable Frequency Drive

Product Details
Customization: Available
Task: Adjust
Structure: Open-Loop
Still deciding? Get samples of US$ 90/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 6 patents, you can check the Audit Report for more information
to see all verified strength labels (26)
  • Unimat VFD 3kw Three Phase Variable Frequency Drive
  • Unimat VFD 3kw Three Phase Variable Frequency Drive
  • Unimat VFD 3kw Three Phase Variable Frequency Drive
  • Unimat VFD 3kw Three Phase Variable Frequency Drive
  • Unimat VFD 3kw Three Phase Variable Frequency Drive
  • Unimat VFD 3kw Three Phase Variable Frequency Drive
Find Similar Products

Basic Info.

Model NO.
RV32-T3-2R2G/3P
Mathematical Model
Linear
Signal
Continuous
Function
Automatic Control
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Non-Customized
Material
ABS
Power
0.75-11kw
Color
Gray
Weight
0.75kgs
Name
VFD
Transport Package
Carton Packing
Specification
size: 40*125*120mm
Trademark
UniMAT
Origin
China
Production Capacity
500, 000/Year

Product Description

Product Summary
*
Compact structure design, saves installation space
Clear terminal layout marking, easier to install
Wide voltage range design ensures the adaptability of products to power network fluctuations
Advanced independent duct design, adapt to a variety of complex, harsh site environment
 
Strong and Weak Electrical Isolation Design
Adopt srtong & week electrical isolation Design, to avoid magnetic field
interference and increase service lift.
 
Heat Dissipation Structure
Independent cooling duct optimization design, from the original right
angle optimization to rounded corner, reduce the thermal disk
accumulation, greatly increase the efficiency of heat dissipation.
After heat dissipation optimization, based on the previous structure to
reduce the side heat dissipation hole , the actual protection level can be
up to IP40, the protection performance is far ahead of similar products.
 
Laminated Structure
BUS capacitor board and POWER motherboard laminated design. The
BUS capacitor board is arranged in an independent cooling air duct to
effectively dissipate heat.
The new design of laminated bus can reduce stray inductance, reduce
peak voltage and protect IGBT. At the same time, compact structure,
save installation space.
 
High Protection Structure Design
The inlet and outlet of the copper bar are closed with rubber rings,
which can effectively isolate the external dust and corrosive gas.
Epoxy partition is added to isolate the circuit installation area and form
an independent internal space to avoid damage to the circuit board
from the external environment and extend the service life
Unimat VFD 3kw Three Phase Variable Frequency Drive
.
Product configuration
Basic application functions
Torque raise at low frequency To improve low frequency torque about 0.1%-30% under V/f control and
sensorless speed vector control through raising voltage and torque..
V/F Curve Linear type, multi-point type
Acceleration
and deceleration curve
Linear or S-shaped acceleration and deceleration; three sets of acceleration and
deceleration time; acceleration and deceleration time range: 0-3200s
Automatic Voltage Regulation (AVR) When the grid voltage changes, it can automatically keep the output voltage constant
Built-in PID Convenient to realize process control under close-loop control system.
DC braking DC braking range: 0.0Hz-maximum frequency; braking time: 0.0s-20.0s
Braking action current value: 0%-100%
Jog control To realize instant start and instant stop; jog frequency setting range:
0-20Hz; jog stop type: freedom/DC brake
Frequency Hopping Available to set three jump frequency points and related jump
frequency ranges
Multi-speed Up to 15 operating frequencies can be set via logic input terminals
Input Sum The algebraic operation result of 2 analog inputs is used as the frequency setting,
making the frequency setting more flexible
2 sets of motor parameter switching Two sets of motor parameters can be set and switched freely to match the currently
driven motor
Inverter protection Input phase failure, output phase failure, under load monitor, over torque, under
voltage, over current, over heat, short circuit among three phases
Motor protection Motor overheat, motor current limiting amplitude, motor over load, motor
short circuit
Electrical characteristics
Input voltage Three-phase AC, 380-480V, 50/60Hz 
Output voltage 0-480V, 0.5Hz-400Hz
Control Mode V/F control for constant torque, V/F control for quadratic load, vector control
without PG, Energy-saving mode
Switching frequency 1.5kHz - 12kHz
 according to junction temperature automatically reduce the
switching frequency
Overload capability 150% rated output current for 60s, 200% rated output current for 2s
Control signal
Frequency setting signal Integrated operating panel Film switch (Press button), speed control knob
(potentiometer)
Outside Signal UP/DOWN setting, analog input, multi-speed, remote keypad, serial communication
Start-stop
control signal
Integrated operating panel RUN, STOP buttons
Outside Signal Logic input terminal,  remote keypad, serial communication
Protective function
Inverter protection Input phase loss protection, output phase loss protection, underload detection,
over-torque protection, undervoltage protection, overvoltage protection, overcurrent
protection, overheating protection, phase short circuit protection
Motor protection Motor thermal protection, motor current limiting, motor overload, motor short circuit
Control circuit characteristics
Available inside power supply 5V
24V
5V DC 5%, maximun current 10mA, it is used for benchmark potentiometer
24V DC 5%, maximum current 100mA, it is used for logic input entrance
Analog Input AI1 Voltage analog input: 0-5VDC, or 0-10VDC, impedance 30kΩ
Current analog input: 0/4-20mADC, impedance 250Ω
Resolution: 10-bit A/D conversion
Factory default setting: 0-5VDC voltage input
AI2 Voltage analog input: 0-10VDC, or PTC probe input
Resolution: 10-bit A/D conversion
Logic Input LI1-LI8 0-24VDC power supply
Positive logic (source), negative logic (sink) are optional, the factory default is
negative logic
69 functions are available, including forward, reverse, running, fault reset,
multi-speed, etc.
Only 6 ways below 11KW (including): LI1-LI6
AI1,AI2 AI1 and Al2 could be set to logic input for RV32 frequency inverter with
power below (including) 11 kW.

Mandatory
effective input
F309 and F310 are mandatory effective input.
It will guarantee the set function effective during powering on.
Analog Output AO1,AO2 Voltage analog output: 0-10V DC, minimum load impedance is 470Ω
Current analog output: 0-20mA, maximum load impedance is 700Ω
Resolution: 8 digital
Logic Output LO,CLO Open collector, maximum current 100mA, maximum voltage 30VDC
Optional for logic output or pulse output, factory default is logic output
Output frequency, output current and given speed are optional
Relay output T1A,T1B,T1C
T2A
,T2B,T2C
T1A constant open, T1B constant close, T1C public Point
T2A constant open, T2 B constant close, T 2C public point
Touch point capacity: 5A@250VAC, 5A@30VDC
Many functions optional such as fault, alarm and set frequency reach
Serial Communication MODBUS-RTU, 2-wire RS-485,  RJ45 connection port
Environmental characteristics
Ingress protection  IP20 environment humidity No condensed water or drip at 5~95%,
In accordance with IEC60068-2-3
Installation place Altitude
Working temperature/storage temperature "- 10~50ºC /- 20~60ºC Installation place room
cooling method Forced air cooling Altitude 1000m or below (Derating is necessary
when the altitude is higher than 1000m)
Unimat VFD 3kw Three Phase Variable Frequency DriveUnimat VFD 3kw Three Phase Variable Frequency Drive


Basic application functions
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier