Cheap and Replace S7 200 PLC with 24 Io

Product Details
Customization: Available
Task: Program
Structure: Combination
Still deciding? Get samples of US$ 150/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 6 patents, you can check the Audit Report for more information
to see all verified strength labels (26)
  • Cheap and Replace S7 200 PLC with 24 Io
  • Cheap and Replace S7 200 PLC with 24 Io
  • Cheap and Replace S7 200 PLC with 24 Io
  • Cheap and Replace S7 200 PLC with 24 Io
  • Cheap and Replace S7 200 PLC with 24 Io
  • Cheap and Replace S7 200 PLC with 24 Io
Find Similar Products

Basic Info.

Model NO.
UN 124-2BD23-0XB8
Signal
Continuous
Function
Automatic Control
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Customized
Material
ABS
Economical
Small
Compatible
Stable
Transport Package
CTN
Specification
CE, TUV ISO9001, SGS
Trademark
UniMAT
Origin
China
HS Code
9032900090
Production Capacity
50, 000 PCS/Yr

Product Description

Product Descriptions :

1. Order Number: UN 124-2BD23-0XB0  

2. Local digital Inputs & Outputs: 14DC/10DO,  

3. Appropriate computering and data processing, external connection with three I/O Expansion modules, long-time data-holding on power-off,  

4. Unique AES Iterative encryption algorithm,which protects clients' intellectual property,  

5. Allowing up to two communication ports, both support PPI protocol. 

Technical specifications

Model

CPU124-2R DC/DC/RLY

Physical characteristic

Dimensions(W x H x D)(mm)

120.5×80×62

Power consume

7W

Memory

Program memory size

8K 

Data memory

10K

Back up (by Flash, no need battery)

keep over 10 years

I/O

Local digital inputs

14 inputs

Local digital outputs

10 outputs

Digital I/O image size

128(64 inputs/64 outputs)

Analog I/O image size

32(16 inputs/16 outputs)

expansion modules allowed (Max)

3 modules

Pulse catch inputs

14

High-speed counters

6 counters total

Single phase

6 at 30KHz

Two phase

4 at 20KHz

Pulse outputs

2 at 20KHz(DC outputs only)

General

Timer

Total number:256(1ms:4;10ms:16;100ms:236)

Counters

256

Internal memory bits stored on power down

256

Time interrupts

2 with1ms resolution

Edge interrupts

4 up and/or 4 down

Analog adjustment

2 with 8 bit resolution

Boolean execution speed

0.08µs per instruction

Real Time Clock

Built-in

Ports

2 RS-485 ports,witnin 1 standard PPI port

PPI Baud Rates

9.6,19.2 and 187.5 Kbaud

Freeport Baud Rates

1.2kbaud to 115.2Kbaud

Max. cable length per segment

With isolated repeater:1000 m up to 187.5kbaud, 1200 m up to 38.4kbaud

Without isolated repeater: 50 m

Max. number of stations

32 per segment, 126 per network

Max. number of masters

32

Peer to peer(PPI Master Mode)

no

Power

Input voltage

20.4 to 28.8 VDC

Inrush current

12A at 28.8 VDC

Isolation(field to logic)

Not isolated

Hold up time(loss of power)

10ms at 24 VDC

Sensor voltage

L+ minus 5 V

Current limit

1.5A peak,thermal limit non-destructive

Ripple noise (sensor to logic)

Derived from input power

Isolation (sensor to logic)

Not isolated

CPU Digital Input Specifications

Built-in digital input

14

Input type

PNP/NPN

Rated voltage

24 VDC at 4mA

Max. continuous  permissible voltage

30 VDC

Surge voltage

35 VDC for 0.5s

Logic "1"  voltage range

15 to 30 VDC

Logic "0"  voltage range

0 to 5 VDC

Input delay

Selectable (0.2 to12.8ms)

Connection of 2-wire proximity sensor (Bero)

Premissible leakage current (Max.)

1mA

Isolation (field to logic)

Yes

Optical galvanic

500 VAC for 1minute

High-speed Counters

single-phase 2 pcs 20K(I0.0 I0.1)

Cable length Max.

 

Shielded

500m normal inputs, 50m HSC inputs

unshielded

300m normal inputs

CPU Digital Output Specifications

Built-in outputs

10 outputs

Output type

Dry contact

Rated voltage

24 VDC or 250V AC

Voltage range

5-30V DC,5-250V AC

Surge current (Max.)

5A 4s at 10% duty cycle

Logic "1"  (Min)

-

Logic "0"  (Max)

-

Rated current per point(Max.)

2A

Rated current per common(Max)

8A

Leakage current (Max)

-

Lamp load (Max)

30W DC,200W AC

Inductive clamp voltage

-

On State resistance (contact)

0.2Ω

Isolation

Relay  Isolation

Pulse frequency (Max.)

1Hz

Lifetime mechanical cycles

10000000(no load)

Lifetime contacts

100000(Rated load)

Outputs on simultaneously

All at 60ºC(horizontal)

All at 50ºC (Vertical)

Connecting two outputs in parallel

Yes, only outputs in same group

Cable Length (Shielded)

500m

Cable Length (unshielded)

150m

Order number

UN 124-2BD23-0XB0


Cheap and Replace S7 200 PLC with 24 Io
Cheap and Replace S7 200 PLC with 24 IoCheap and Replace S7 200 PLC with 24 Io



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now