Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital

Product Details
Customization: Available
Task: Program
Structure: Combination
Still deciding? Get samples of US$ 200/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 6 patents, you can check the Audit Report for more information
to see all verified strength labels (26)
  • Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
  • Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
  • Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
  • Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
  • Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
  • Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
Find Similar Products

Basic Info.

Model NO.
UN 216-2BD23-0XB0
Mathematical Model
Linear
Signal
Discrete
Function
Automatic Control
Certification
ISO: 9001, CE
Condition
New
Customized
Customized
Material
ABS
Transport Package
CTN
Specification
CE, SGS, TUV ISO9001
Trademark
UniMAT
Origin
China
HS Code
853710119
Production Capacity
50, 000/Year

Product Description


Chinese CPU 24DI / 16DO , AC / DC / RELAY Programming Logic Controller CPU

1). 24DI, 16 DO with Relay

2). Communication Ports: 2RS - 485, both support PPI protocol ; 

3). Supports expansion modules : 7 modules ;

4). Compatible with Siemens 224 CPU ;

5). 3 year warranty ;

6). Siemens software is ok.

 

Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
Unimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 DigitalUnimat CPU 226 Replace 6es7 216-2bd23-0xb0 Relay CPU of PLC with 40 Digital
Model CPU226 AC/DC/Relay
Physical characteristic  
Dimensions(W x H x D)(mm) 196× 80× 62
Power consume 17W
Memory   
Program memory size  
With run mode edit 36K bytes
Without run mode edit 72K bytes
Data memory 40960bytes
I/O  
Local digital inputs 24 inputs
Local digital outputs 16 outputs
Digital I/O image size 256(128 inputs/128 outputs)
Analog I/O image size 64(32 inputs/32 outputs)
expansion modules allowed (Max) 7 modules
intelligent modules allowed (Max) 7 modules
Pulse catch inputs 24
High-speed counters 6 counters total
Single phase 6 at 30KHz
Two phase 4 at 20KHz
Pulse outputs -
General  
Timer Total number: 512(1ms: 8; 10ms: 32; 100ms: 472)
Counters  512
Internal memory bits stored on power down 512
Time interrupts 2 with 1ms resolution
Edge interrupts 4 up and/or 4 down
Analog adjustment 2 with 8 bit resolution
Boolean execution speed 0.08µ s per instruction
Real Time Clock Built-in
Communications Built-in  
Ports 2 RS-485 ports, within1standard PPI port
PPI Baud Rates 9.6, 19.2 and 187.5 kbaud
Freeport Baud Rates 1.2kbaud to 115.2kbps
Max. cable length per segment With isolated repeater: 1000 m up to 187.5kbaud, 1200 m up to 38.4kbaud
Without isolated repeater: 50 m
Max. number of stations 32 per segment, 126 per network
Max. number of masters 32
Peer to peer(PPI Master Mode) Yes
Power  
Input voltage 85 to 264 V AC(47 to 63Hz)
Input current 60/30mA while CPU only at 120/240V AC
200/100Ma while Max. load at 120/240V AC
Inrush current 20A at 264 V AC
Isolation(field to logic) 1500 V AC
Hold up time(loss of power) 1s at 120/240 V AC
Sensor voltage 20.4 to 28.8 V DC
Current limit 1.5A peak, thermal limit non-destructive
Ripple noise (sensor to logic) Less than 1 V peak-to-peak
Isolation (sensor to logic) Not isolated
CPU Digital Input Specifications  
Built-in digital inputs 24
Input type PNP/NPN
Rated voltage 24 V DC at 4mA
Max. continuous  permissible voltage 30V DC
Surge voltage 35 V DC, 0.5s
Logic " 1"   voltage range 15 to 30 V DC
Logic " 0"   voltage range 0 to 5 V DC
Input delay Selectable (0.2 to 12.8ms)
Connection of 2-wire proximity sensor (Bero) 1mA
Premissible leakage current (Max. )
Isolation (field to logic) Yes
Optical galvanic 500 V AC for 1minute
Isolation groups Refer to Wiring diagram
High Speed Counter (HSC) input rate  
HSC logic level 1(15 TO 30 V DC) 20K Hz (Single phase), 10K Hz (Tow phase)
HSC logic level 1(15 TO 26 V DC) 30K Hz (Single phase), 20K Hz (Tow phase),
Inputs on simultaneously all
Cable length Max.  
Shielded 500m normal inputs, 50m HSC inputs
unshielded 300m normal inputs
CPU Digital Output Specifications  
Built-in outputs 16 outputs
Output type Dry contact
Rated voltage 24 V DC or 250 V AC
Voltage range 5 to 30 V DC or 5 to 250 V AC
Surge current (Max. ) 5A for 4s at 10% duty cycle
Logic " 1"   (Min) -
Logic " 0"   (Max) -
Rated current per point(Max. ) 2.0A
Rated current per common(Max. ) 10A
Leakage current (Max) -
Lamp load (Max) 30W DC; 200W AC
Inductive clamp voltage  
On State resistance (contact) 0.2Ω (max. when new)
Isolation  
Optical (galvanic, field to logic) -
logic to contact 1500 V AC for 1 minute
Resistance (logic to contact) 100MΩ
Isolation groups Refer to wiring diagram
Delay(Max)  
Off to on -
On to off -
Switching 10ms
Pulse frequency (Max. ) 1Hz
Lifetime mechanical cycles 10, 000, 000 (no load)
Lifetime contacts 100, 000 (rated load)
Outputs on simultaneously All at 60C(horizontal)
All at 50C (Vertical)
Connecting two outputs in parallel No
Cable Length (Shielded) 500m
Cable Length (unshielded) 150m
Order number UN 216-2BD23-0XB0